• Türkçe
    • English
  • Türkçe 
    • Türkçe
    • English
  • Giriş
Öğe Göster 
  •   RTEÜ
  • Araştırma Çıktıları | TR-Dizin | WoS | Scopus | PubMed
  • Scopus İndeksli Yayınlar Koleksiyonu
  • Öğe Göster
  •   RTEÜ
  • Araştırma Çıktıları | TR-Dizin | WoS | Scopus | PubMed
  • Scopus İndeksli Yayınlar Koleksiyonu
  • Öğe Göster
JavaScript is disabled for your browser. Some features of this site may not work without it.

A facile and sensitive coprecipitation method coupled with flame atomic absorption spectrometry for quantification of Cu(II) ions in complex matrices

Thumbnail

Göster/Aç

Full Text / Tam Metin (2.064Mb)

Erişim

info:eu-repo/semantics/openAccess

Tarih

2023

Yazar

Özdeş, Duygu
Duran, Celal
Bektaş, Hakan
Menteşe, Emre

Üst veri

Tüm öğe kaydını göster

Künye

Ozdes, D., Duran, C. ., Bektas, H., & Mentese, E. . (2022). A facile and sensitive coprecipitation method coupled with flame atomic absorption spectrometry for quantification of Cu(II) ions in complex matrices: Scientific paper. Journal of the Serbian Chemical Society, 88(3). https://doi.org/10.2298/JSC220122074O

Özet

In the present investigation, the application of an organic coprecipitant, 2-[5,6-dichloro-2-(2-bromobenzyl)-1H-benzimidazole-1-yl]acetohydrazide (DIBBA), for separation and preconcentration of Cu(II) ions in fruit and water samples through a new carrier element free coprecipitation (CEFC) method was researched for the first time. Flame atomic absorption spectrometer (FAAS) was used for the analyses of Cu(II) ions. The main effective experimental factors such as solution pH, DIBBA quantity, waiting time, centrifuge speed and duration and volume of sample on the recovery efficiency of Cu(II) ions were explored in detail. Under the optimized conditions the preconcentration factor (PF), relative standard deviation (RSD), and limits of detection (LOD) was achieved as 50, 3.4 % and 0.44 µg L-1, respectively. No interference effects were detected by virtue of the presence of various foreign ions. Satisfactory recoveries (in the range of 94.4 to 103.0 %) in the environmental sample matrix were acquired. After being validated the recommended selective, low cost, simple and rapid CEFC method by spike/recovery tests, it was properly implemented for the low levels detection of Cu(II) ions in sour cherry, mulberry, apple, and peach as fruit samples and stream and sea water samples without any significant matrix effects.

Kaynak

Journal of the Serbian Chemical Society

Cilt

88

Sayı

3

Bağlantı

https://doi.org/10.2298/JSC220122074O
https://hdl.handle.net/11436/8392

Koleksiyonlar

  • FEF, Kimya Bölümü Koleksiyonu [474]
  • Scopus İndeksli Yayınlar Koleksiyonu [5917]



DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 




| Yönerge | Rehber | İletişim |

DSpace@RTEÜ

by OpenAIRE
Gelişmiş Arama

sherpa/romeo

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına GöreBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına Göre

Hesabım

GirişKayıt

İstatistikler

Google Analitik İstatistiklerini Görüntüle

DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 


|| Rehber|| Yönerge || Kütüphane || Recep Tayyip Erdoğan Üniversitesi || OAI-PMH ||

Recep Tayyip Erdoğan Üniversitesi, Rize, Türkiye
İçerikte herhangi bir hata görürseniz, lütfen bildiriniz:

Creative Commons License
Recep Tayyip Erdoğan Üniversitesi Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@RTEÜ:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.