Basit öğe kaydını göster

dc.contributor.authorZagane, Mohammed El Sallah
dc.contributor.authorAbdelmadjid, Moulgada
dc.contributor.authorYaylacı, Murat
dc.contributor.authorAbderahmen, Sahli
dc.contributor.authorYaylacı, Ecren Uzun
dc.date.accessioned2024-02-12T06:25:09Z
dc.date.available2024-02-12T06:25:09Z
dc.date.issued2023en_US
dc.identifier.citationZagane, M.E., Abdelmadjid, M., Yaylacı, M., Abderahmen, S. & Yaylacı, E.U. (2023). Finite element analysis of the femur fracture for a different total hip prosthesis (Charnley, Osteal, and Thompson). Structural Engineering and Mechanics, 88(6). https://doi.org/10.12989/sem.2023.88.6.583en_US
dc.identifier.issn1225-4568
dc.identifier.issn1598-6217
dc.identifier.urihttps://doi.org/10.12989/sem.2023.88.6.583
dc.identifier.urihttps://hdl.handle.net/11436/8770
dc.description.abstractTotal hip replacement is a crucial intervention for patients with fractured hips who face challenges in natural recovery. The design of durable prostheses requires a comprehensive understanding of the natural processes occurring in bone. This article focuses on static loading analysis, specifically during stumbling activity, aiming to enhance the longevity of prosthetic implants. Three distinct implants, Charnley, Osteal, and Thompson, were selected for a detailed study to determine the most appropriate model. The results revealed critical insights into the distribution of Von Mises stresses on the components of femoral arthroplasty, including the cement, implant, and cortical bone. Furthermore, the examination of shear stress within the cement emerged as a pivotal aspect for all three implants, playing a crucial role in evaluating the performance and durability of hip prostheses. The conclusions drawn from this study strongly suggest that the Thompson model stands out as the most suitable choice for hip joint implants.en_US
dc.language.isoengen_US
dc.publisherTechno-Pressen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectCementen_US
dc.subjectFinite element methoden_US
dc.subjectStressen_US
dc.subjectTotal hip prosthesisen_US
dc.titleFinite element analysis of the femur fracture for a different total hip prosthesis (Charnley, Osteal, and Thompson)en_US
dc.typearticleen_US
dc.contributor.departmentRTEÜ, Mühendislik ve Mimarlık Fakültesi, İnşaat Mühendisliği Bölümüen_US
dc.contributor.institutionauthorYaylacı, Murat
dc.contributor.institutionauthorYaylacı, Ecren Uzun
dc.identifier.doi10.12989/sem.2023.88.6.583en_US
dc.identifier.volume88en_US
dc.identifier.issue6en_US
dc.relation.journalStructural Engineering and Mechanicsen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster