• Türkçe
    • English
  • Türkçe 
    • Türkçe
    • English
  • Giriş
Öğe Göster 
  •   RTEÜ
  • Araştırma Çıktıları | TR-Dizin | WoS | Scopus | PubMed
  • WoS İndeksli Yayınlar Koleksiyonu
  • Öğe Göster
  •   RTEÜ
  • Araştırma Çıktıları | TR-Dizin | WoS | Scopus | PubMed
  • WoS İndeksli Yayınlar Koleksiyonu
  • Öğe Göster
JavaScript is disabled for your browser. Some features of this site may not work without it.

Effects of contrast limited adaptive histogram equalization (CLAHE) on manual and automated tracing of lateral cephalometric radiographs

Göster/Aç

Tam Metin / Full Text (1.588Mb)

Erişim

info:eu-repo/semantics/openAccess

Tarih

2024

Yazar

Gonca, Merve
Turgut, Çiğdem Sazak
Gündoğdu, Şeyma

Üst veri

Tüm öğe kaydını göster

Künye

Gonca, M., Sazak, Ç., & Gündoğdu, Ş. (2024). Effects of Contrast Limited Adaptive Histogram Equalization (CLAHE) on Manual and Automated Tracing of Lateral Cephalometric Radiographs. Clinical and Experimental Health Sciences, 14(3), 733-744. https://doi.org/10.33808/clinexphealthsci.1357008

Özet

Objective: The aim of this study is to compare the difference between original lateral cephalometric radiographs (LCRs) and Contrast Limited Adaptive Histogram Equalization (CLAHE) LCRs in two examiners and WebCeph. Methods: A total of 200 LCRs were selected, and CLAHE (tile size: 20*20) was applied to the original LCRs. 27 LCR landmarks were manually determined by two examiners and, the selected LCR's determined automatically using the WebCeph program. Absolute differences between the original LCRs and CLAHE-LCRs were calculated in the x-y axes and Euclidean distance. The Kruskal Wallis test was used for comparisons between the examiners and WebCeph. The Wilcoxon Signed Rank Test was used to evaluate the x and y axes within each group. Results: The best accuracy values were seen in examiner 1 along the x-y axes and Euclidean distance, while the worst accuracy values were seen in WebCeph. The mean differences according to the methods were higher along the y-axis than along the x-axis for both examiners (except PNS, Me') and WebCeph (except Po, Co). The mean Euclidean distances were above 2 mm only in Co, PNS at Examiner 1, PNS, Po, Ba, Co, Go, Pog, U1RT, Me', Pog at Examiner 2, and WebCeph in all measurements. However, the differences in Euclidean distances were less than 4 mm for both examiners and WebCeph. Conclusion: CLAHE-LCRs require more adjustments for landmark determination in WebCeph than the in the manual system.

Kaynak

Clinical and Experimental Health Sciences

Cilt

14

Sayı

3

Bağlantı

https://doi.org/10.33808/clinexphealthsci.1357008
https://hdl.handle.net/11436/9692

Koleksiyonlar

  • DŞHF, Klinik Bilimler Bölümü Koleksiyonu [244]
  • WoS İndeksli Yayınlar Koleksiyonu [5260]



DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 




| Yönerge | Rehber | İletişim |

DSpace@RTEÜ

by OpenAIRE
Gelişmiş Arama

sherpa/romeo

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına GöreBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına Göre

Hesabım

GirişKayıt

İstatistikler

Google Analitik İstatistiklerini Görüntüle

DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 


|| Rehber|| Yönerge || Kütüphane || Recep Tayyip Erdoğan Üniversitesi || OAI-PMH ||

Recep Tayyip Erdoğan Üniversitesi, Rize, Türkiye
İçerikte herhangi bir hata görürseniz, lütfen bildiriniz:

Creative Commons License
Recep Tayyip Erdoğan Üniversitesi Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@RTEÜ:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.