Can wideband tympanometry be used as a screening test for superior semicircular canal dehiscence?

dc.contributor.authorDemir, Emine
dc.contributor.authorAfacan, Nazife Nur
dc.contributor.authorÇeliker, Metin
dc.contributor.authorÇeliker, Fatma Beyazal
dc.contributor.authorİnecikli, Mehmet Fatih
dc.contributor.authorTerzi, Suat
dc.contributor.authorDursun, Engin
dc.date.accessioned2020-12-19T19:36:42Z
dc.date.available2020-12-19T19:36:42Z
dc.date.issued2019
dc.departmentRTEÜ, Tıp Fakültesi, Cerrahi Tıp Bilimleri Bölümü
dc.descriptionDemir, Emine/0000-0003-4087-432X; INECIKLI, MEHMET FATIH/0000-0002-9796-8223; DURSUN, Engin/0000-0002-2070-8677
dc.description.abstractObjectives. We explored whether wideband tympanometry (WBT) could be used as a screening test for superior semicircular canal dehiscence (SSCD), and obtained new WBT data (given that the test is not yet in common clinical use) on patients with SSCD. Methods. We compared the WBT data of patients clinically and radiologically diagnosed with SSCD in our hospital between 2013 and 2018 to those of healthy volunteers. We compared the resonance frequency (RF), maximum absorbance frequency (MAF), and maximum absorbance ratio (MAR). M`he t-test was used for statistical analysis with the significance level set to P< 0.05. in addition, we used receiver operating characteristic analysis to derive cutoff values for SSCD diagnosis in terms of sensitivity and specificity. Results. Seventeen patients (four with bilateral and 13 with unilateral disease; 17 ears) diagnosed with SSCD and 27 healthy volunteers (47 ears) were included.The mean RFs of the SSCD patients and healthy subjects were 548.7 Hz (range, 243 to 853 Hz) and 935.1 Hz (range, 239 to 1,875 Hz), respectively (P<0.001). the mean MARs of the SSCD patients and healthy subjects were 89.4% (range, 62% to 100%) and 82.4% (range, 63% to 99%), respectively (P=0.005). the mean MAFs of the SSCD patients and healthy subjects were 1,706.3 Hz (range, 613 to 3,816 Hz) and 2,668 Hz (range, 876 to 4,387 Hz), respectively (P<0.001). in terms of SSCD diagnosis, a MAR above 86% afforded 81% sensitivity and 77% specificity; an RF below 728 Hz, 86% sensitivity and 81% specificity; and an MAF below 1,835 Hz, 79% sensitivity and 67% specificity. Conclusion. WBT may be a useful clinical screening test for SSCD. the RF and MAF were lower, and the MAR higher, in SSCD patients than in normal controls.
dc.identifier.citationDemir, E., Afacan, N. N., Celiker, M., Celiker, F. B., İnecikli, M. F., Terzi, S., & Dursun, E. (2019). Can Wideband Tympanometry Be Used as a Screening Test for Superior Semicircular Canal Dehiscence?. Clinical and experimental otorhinolaryngology, 12(3), 249–254. https://doi.org/10.21053/ceo.2018.01137
dc.identifier.doi10.21053/ceo.2018.01137
dc.identifier.endpage254
dc.identifier.issn1976-8710
dc.identifier.issn2005-0720
dc.identifier.issue3
dc.identifier.pmid30458602
dc.identifier.scopus2-s2.0-85069678604
dc.identifier.scopusqualityQ1
dc.identifier.startpage249
dc.identifier.urihttps://doi.org/10.21053/ceo.2018.01137
dc.identifier.urihttps://hdl.handle.net/11436/1470
dc.identifier.volume12
dc.identifier.wosWOS:000474448600006
dc.identifier.wosqualityQ2
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.institutionauthorDemir, Emine
dc.institutionauthorAfacan, Nazife Nur
dc.institutionauthorÇeliker, Metin
dc.institutionauthorÇeliker, Fatma Beyazal
dc.institutionauthorİnecikli, Mehmet Fatih
dc.institutionauthorTerzi, Suat
dc.institutionauthorDursun, Engin
dc.language.isoen
dc.publisherKorean Soc Otorhinolaryngol
dc.relation.ispartofClinical and Experimental Otorhinolaryngology
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.snmzKA_20201219
dc.subjectTympanometry
dc.subjectSemicircular canal
dc.subjectDehiscence
dc.subjectResonance frequency
dc.subjectAcoustic impedance test
dc.titleCan wideband tympanometry be used as a screening test for superior semicircular canal dehiscence?