Performance analysis of the impact of sloped absorber dimensions on the performance of solar chimney power plants

dc.contributor.authorBenettayeb, Youcef
dc.contributor.authorBenbouali, Abderrahmen
dc.contributor.authorTahri, Toufik
dc.contributor.authorCüce, Erdem
dc.date.accessioned2025-09-18T07:39:10Z
dc.date.issued2025
dc.departmentRTEÜ, Mühendislik ve Mimarlık Fakültesi, Makine Mühendisliği Bölümü
dc.description.abstractSeveral geometric parameters have been investigated in solar chimney power with the aim of determining the optimal geometric parameters and enhancing power generation. The aim of this study is to determine the optimal dimensions of the sloped absorber surface and analyze its impact on the power output of the system at the Manzanares plant. The sloped absorber surface studied includes a singular triangular shape where the effect of the central high and absorber slope radius is studied. To conduct this study, A Computational Fluid Dynamics CFD model developed using COMSOL Multiphysics with the k–ε turbulence model was employed. The outcomes of this study demonstrate that the maximum air velocity in the reference Manzanares design, initially measured at 15 m s−1, increases by 26% with the optimized sloped absorber configuration. Specifically, at a central height of 1.10 m and an absorber slope radius of 122 m, the maximum velocity reaches 18.9 m s−1. Furthermore, the power output rises by 34%, reaching 67 kW compared to the reference case of 50 kW.
dc.identifier.citationBenettayeb, Y., Benbouali, A., Tahri, T. ve Cuce, E. (2025). Eğimli soğurucu boyutlarının güneş bacası enerji santrallerinin performansı üzerindeki etkisinin performans analizi. Termal Analiz ve Kalorimetri Dergisi , 150 (12), 9561–9571. https://doi.org/10.1007/s10973-025-14307-4
dc.identifier.doi10.1007/s10973-025-14307-4
dc.identifier.endpage9571
dc.identifier.issn1388-6150
dc.identifier.issue12
dc.identifier.scopus2-s2.0-105005553506
dc.identifier.scopusqualityQ1
dc.identifier.startpage9561
dc.identifier.urihttps://doi.org/10.1007/s10973-025-14307-4
dc.identifier.urihttps://hdl.handle.net/11436/11132
dc.identifier.volume150
dc.identifier.wosWOS:001502197500001
dc.identifier.wosqualityQ2
dc.indekslendigikaynakScopus
dc.indekslendigikaynakWeb of Science
dc.institutionauthorCüce, Erdem
dc.institutionauthorid0000-0003-0150-4705
dc.language.isoen
dc.publisherSpringer
dc.relation.ispartofJournal of Thermal Analysis and Calorimetry
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectAbsorber slope radius
dc.subjectCentral high
dc.subjectPower output
dc.subjectSloped absorber surface
dc.subjectSolar chimney power plants
dc.subjectTemperature
dc.subjectVelocity
dc.titlePerformance analysis of the impact of sloped absorber dimensions on the performance of solar chimney power plants
dc.typeArticle

Dosyalar

Orijinal paket

Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
youcef-2025.pdf
Boyut:
1.23 MB
Biçim:
Adobe Portable Document Format

Lisans paketi

Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
license.txt
Boyut:
1.17 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: