Evaluation of the effects of Er:YAG laser, Nd:YAG laser, and two different desensitizers on dentin permeability: in vitro study

dc.contributor.authorKurt, Sevda
dc.contributor.authorKırtıloplu, Tuğrul
dc.contributor.authorYılmaz, Nasibe Aycan
dc.contributor.authorErtaş, Ertan
dc.contributor.authorOruçoğlu, Hasan
dc.date.accessioned2020-12-19T19:41:04Z
dc.date.available2020-12-19T19:41:04Z
dc.date.issued2018
dc.departmentRTEÜ, Diş Hekimliği Fakültesi, Klinik Bilimler Bölümü
dc.descriptionYilmaz, Nasibe Aycan/0000-0001-5939-8170; KURT, Sevda/0000-0002-3711-6520
dc.description.abstractThe purpose of this in vitro study was to evaluate and compare the efficacy of erbium-doped yttrium aluminum garnet (Er:YAG) laser, neodymium-doped yttrium aluminum garnet (Nd:YAG) laser, PrevDent nano-hydroxyapatite toothpaste plus Repairing Serum Kit (PNH), and NUPRO Sensodyne Prophylaxis Paste with NovaMin (NPP) on dentin permeability reduction. Forty dentin discs obtained from bovine incisors were divided into four study groups: Er:YAG laser-treated (2940nm; 0.2W, 80mJ/pulse, 3Hz); Nd:YAG laser-treated (1064nm; 1W, 10Hz); PNH-treated; and NPP-treated groups. the quantitative changes in permeability of each dentin disc were measured using a computerized fluid filtration method (CFFM) before and after desensitizer treatments. the data were analyzed using the Wilcoxon, paired-samples t, Kruskal-Wallis, and Mann-Whitney U tests. the dentin surfaces and tubules were also morphologically detected by scanning electron microscopy (SEM). in all groups, dentin permeability was significantly reduced after the desensitizer and laser treatments (p<0.05). Among the groups, we detected a significant difference in only when comparing the Er:YAG laser- and NPP-treated groups (p=0.034). SEM analysis revealed physical changes in the dentin surface in all groups. This in vitro study shows that all tested desensitizers and laser treatments reduced dentin permeability. Also, surface changes, such as complete or partial occlusion or shrinkage of dentin tubules, were observed in all groups. Although the laser groups performed best, the PNH protocol can be considered as an alternative therapeutic product. in addition, clinical and laboratory studies should be performed for this product, and their efficacy should be assessed by combined therapy with lasers.
dc.identifier.citationKurt, S., Kırtıloğlu, T., Yılmaz, N. A., Ertaş, E., & Oruçoğlu, H. (2018). Evaluation of the effects of Er:YAG laser, Nd:YAG laser, and two different desensitizers on dentin permeability: in vitro study. Lasers in medical science, 33(9), 1883–1890. https://doi.org/10.1007/s10103-018-2546-1
dc.identifier.doi10.1007/s10103-018-2546-1
dc.identifier.endpage1890
dc.identifier.issn0268-8921
dc.identifier.issn1435-604X
dc.identifier.issue9
dc.identifier.pmid29850962
dc.identifier.scopus2-s2.0-85047823526
dc.identifier.scopusqualityQ1
dc.identifier.startpage1883
dc.identifier.urihttps://doi.org/10.1007/s10103-018-2546-1
dc.identifier.urihttps://hdl.handle.net/11436/1716
dc.identifier.volume33
dc.identifier.wosWOS:000450033200006
dc.identifier.wosqualityQ2
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.institutionauthorKurt, Sevda
dc.language.isoen
dc.publisherSpringer London Ltd
dc.relation.ispartofLasers in Medical Science
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectDentin sensitivity
dc.subjectDentin permeability
dc.subjectComputerized fluid filtration device
dc.subjectLaser
dc.titleEvaluation of the effects of Er:YAG laser, Nd:YAG laser, and two different desensitizers on dentin permeability: in vitro study
dc.typeArticle

Dosyalar

Orijinal paket

Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
kurt-2018.pdf
Boyut:
3.07 MB
Biçim:
Adobe Portable Document Format
Açıklama:
Full Text / Tam Metin