Experimental investigation of flow boiling in a novel semi-open micro-pin-finned heat sink with regionally decreasing heights under low mass flux
| dc.contributor.author | Markal, Burak | |
| dc.contributor.author | Atci, Fatih | |
| dc.contributor.author | Evcimen, Alperen | |
| dc.contributor.author | Öksüz, Ömer | |
| dc.date.accessioned | 2026-11-18T12:26:45Z | |
| dc.date.issued | 2026 | |
| dc.department | RTEÜ, Mühendislik ve Mimarlık Fakültesi, Makine Mühendisliği Bölümü | |
| dc.description.abstract | This study introduces and experimentally investigates a novel semi-open micro square pin-finned heat sink (DPFH) featuring stage-wise decreasing pin-fin heights to address an identified gap in flow boiling literature. Testing was conducted under a low mass flux of 76 kg m−2 s−1, covering a heating power range from 140 W to 300 W (equivalent to an effective heat flux of 211.8 to 461.4 kW m−2). High-speed flow visualization and thermal metrics were evaluated against a uniform baseline (UPFH). For the DPFH, CHF was not observed even at the maximum heat flux tested, and across the tested operational conditions, the two-phase heat transfer coefficient was enhanced by up to approximately 513% compared with the UPFH. This superior performance stems from the stage-wise expanding passages, which mitigate the adverse hydrodynamic effects of the evaporation momentum force and introduce a supportive unbalanced surface tension force, promoting rapid vapor discharge and rewetting. Flow images uniquely revealed partial bubble breakup in the 100 μm clearance, which is consistent with stronger viscous/shear interactions. Regional variations in Bo, Re, We, Ca, and Co, together with area-normalized force-scale terms, further support the reduced vapor confinement, enhanced vapor discharge, and clearance-dependent bubble deformation observed in the DPFH. Despite a manageable pressure drop penalty of 10.5% to 60.3%, the DPFH achieved a maximum performance evaluation criterion (PEC) of 5.82 and reduced inlet pressure fluctuations by about 46.7%, significantly mitigating flow boiling instabilities. | |
| dc.identifier.citation | Markal, B., Atci, F., Evcimen, A., & Öksüz, Ö. (2026). Experimental investigation of flow boiling in a novel semi-open micro-pin-finned heat sink with regionally decreasing heights under low mass flux. Applied Thermal Engineering, 303, 132478. https://doi.org/10.1016/j.applthermaleng.2026.132478 | |
| dc.identifier.doi | 10.1016/j.applthermaleng.2026.132478 | |
| dc.identifier.issn | 1359-4311 | |
| dc.identifier.scopus | 2-s2.0-105044833405 | |
| dc.identifier.scopusquality | Q1 | |
| dc.identifier.startpage | 132478 | |
| dc.identifier.uri | https://doi.org/10.1016/j.applthermaleng.2026.132478 | |
| dc.identifier.uri | https://hdl.handle.net/11436/13833 | |
| dc.identifier.volume | 303 | |
| dc.indekslendigikaynak | Scopus | |
| dc.institutionauthor | Evcimen, Alperen | |
| dc.institutionauthorid | 0000-0002-5337-5952 | |
| dc.language.iso | en | |
| dc.publisher | Elsevier | |
| dc.relation.ispartof | Applied Thermal Engineering | |
| dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | |
| dc.rights | info:eu-repo/semantics/closedAccess | |
| dc.subject | Flow boiling | |
| dc.subject | Low mass flux | |
| dc.subject | Scaling analysis | |
| dc.subject | Semi-open micro-pin-finned heat sink | |
| dc.subject | Stage-wise decreasing pin-fin heights | |
| dc.title | Experimental investigation of flow boiling in a novel semi-open micro-pin-finned heat sink with regionally decreasing heights under low mass flux | |
| dc.type | Article |











