The impact of high-frequency linear transducer on the accuracy of pelvic ultrasound in early pregnancy pelvic pain and bleeding

dc.contributor.authorÇelik, Ali
dc.contributor.authorYazıcı, Mümin Murat
dc.contributor.authorOktay, Mehmet
dc.date.accessioned2022-12-28T06:04:42Z
dc.date.available2022-12-28T06:04:42Z
dc.date.issued2022
dc.departmentRTEÜ, Tıp Fakültesi, Cerrahi Tıp Bilimleri Bölümü
dc.description.abstractIntroduction: The primary concern of emergency physicians (EPs) in symptomatic patients in their early pregnancy is to rule out ectopic pregnancy by identifying a definite intrauterine pregnancy (IUP). Then an assessment of viability is required for the IUPs. Although transvaginal ultrasound (TVUS) stands as the best modality for these patients, it is not available in most emergency settings. This study aimed to investigate the effects of high-frequency linear transducers (HFLT) on the accuracy of point-of-care ultrasound (POCUS) for detection of IUP and the agreement between EPs and obstetricians for patients' diagnosis. Method: A convenience sample of pregnant patients who presented to the emergency department (ED) with vaginal bleeding and abdominopelvic pain was included. The characteristics of diagnostic tests of transabdominal POCUS performed by EPs were compared to TVUS. Results: The study population was finalized as 143 patients. For the definite IUP, the diagnostic accuracy of POCUS was 93.0%, with a sensitivity of 89.0%, a specificity of 100%, compared to an accuracy of 97.9% for POCUS plus HFLT with a sensitivity of 96.7%, a specificity of 100%. For the identification of fetal cardiac activity (FCA), utilizing HFLT improved the diagnostic accuracy to 97.9% (from 94.4%) and sensitivity to 95.5% (from 88.1%). In addition, the agreement between the EPs and obstetricians concerning the classification of ED diagnosis was excellent (agreement: 96.5%, kappa: 0.943, p < 0.0001). Conclusion: POCUS plus HFLT performed by EPs in evaluating symptomatic patients in their first-trimester pregnancy improves the accuracy to a non-inferior level compared to TVUS performed by obstetricians. Hence, EPs can securely rely on POCUS to confirm IUP and FCA. However, they should be cautious about using it as a rule-out tool. Moreover, HFLT use could enhance the accuracy of POCUS in viability assessment as an alternative to TVUS.
dc.identifier.citationCelik, A., Yazici, M.M. & Oktay, M. (2022). The impact of high-frequency linear transducer on the accuracy of pelvic ultrasound in early pregnancy pelvic pain and bleeding. American Journal of Emergency Medicine, 61, 105-110. https://doi.org/10.1016/j.ajem.2022.08.045
dc.identifier.doi10.1016/j.ajem.2022.08.045
dc.identifier.endpage110
dc.identifier.issn0735-6757
dc.identifier.pmid36063623
dc.identifier.scopus2-s2.0-85137650318
dc.identifier.scopusqualityQ1
dc.identifier.startpage105
dc.identifier.urihttps://doi.org/10.1016/j.ajem.2022.08.045
dc.identifier.urihttps://hdl.handle.net/11436/7288
dc.identifier.volume61
dc.identifier.wosWOS:001094814400004
dc.identifier.wosqualityQ1
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.institutionauthorÇelik, Ali
dc.institutionauthorYazıcı, Mümin Murat
dc.language.isoen
dc.publisherElsevier
dc.relation.ispartofAmerican Journal of Emergency Medicine
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectEmergency medicine
dc.subjectFirst-trimester ultrasound
dc.subjectHigh-frequency linear transducers
dc.subjectIntrauterine pregnancy
dc.subjectPelvic ultrasound
dc.subjectPoint-of-care ultrasound
dc.titleThe impact of high-frequency linear transducer on the accuracy of pelvic ultrasound in early pregnancy pelvic pain and bleeding
dc.typeArticle

Dosyalar

Orijinal paket

Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
çelikk-2022.pdf
Boyut:
529.94 KB
Biçim:
Adobe Portable Document Format
Açıklama:
Full Text / Tam Metin

Lisans paketi

Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
license.txt
Boyut:
1.44 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: