Total Scalp Irradiation: The Comparison of Five Different Plans Using Volumetric Modulated Arc Therapy- Simultaneous Integrated Boost (VMAT-SIB) Technique

dc.contributor.authorYılmaz, Sema Rakıcı
dc.contributor.authorÇınar, Yunus
dc.contributor.authorEren, Mehmet
dc.date.accessioned2020-12-19T20:44:03Z
dc.date.available2020-12-19T20:44:03Z
dc.date.issued2017
dc.departmentRTEÜ
dc.description.abstractThe aim of this study was to show that the optimum dosage can be delivered to the target organs at risk (OAR) by radiotherapy, which becomes more complicated because of technical difficulties arising from irregular, convex, and complex geometrical structure of the target, such as scalp irradiation, and because of situations resulting from the necessity of bolus of the lesion and immobilization as well as the proximity to neighboring critical organs using the VMAT-SIB technique. METHODSFive different VMAT-SIB schemes were designed using the Varian Trilogy IX linear accelerator (Varian Medical Systems) for total scalp irradiation and bilateral neck irradiation. These different VMAT scehemes were compared with respect to a dose volume histogram of obtained data, homogeneity, indices, conformity index, OAR, and doses of target volumes.RESULTSThe patient-designed bolus plan 1 with two isocenters was chosen as the most appropriate plan. Plans 2, 3, 4, and 5 were inappropriate plans because the application of the virtual bolus in plan 2 was difficult, plan 3 with one isocenter was unacceptable with respect to the value of conformity index, plan 4 with three isocenters had a matching field, and plan 5 in which different priority values were used had an increase in OAR doses.CONCLUSIONVMAT-SIB can be preferred as an appropriate radiotherapy technique as it can provide optimum and allowable OAR doses in tumors requiring an intensive treatment planning effort.
dc.identifier.endpage115
dc.identifier.issn1300-7467
dc.identifier.issue3
dc.identifier.startpage106
dc.identifier.urihttps://app.trdizin.gov.tr/makale/TWpRek56QXlNZz09
dc.identifier.urihttps://hdl.handle.net/11436/5953
dc.identifier.volume32
dc.indekslendigikaynakTR-Dizin
dc.language.isoen
dc.relation.ispartofTürk Onkoloji Dergisi
dc.relation.publicationcategoryMakale - Ulusal Hakemli Dergi - Kurum Öğretim Eleman
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_20201219
dc.subjectOnkoloji
dc.titleTotal Scalp Irradiation: The Comparison of Five Different Plans Using Volumetric Modulated Arc Therapy- Simultaneous Integrated Boost (VMAT-SIB) Technique