Internal or external thermal superinsulation towards low/zero carbon buildings? A critical report

dc.contributor.authorCüce, Pınar Mert
dc.contributor.authorCüce, Erdem
dc.contributor.authorAlvur, Emre
dc.date.accessioned2024-09-25T10:41:35Z
dc.date.available2024-09-25T10:41:35Z
dc.date.issued2023
dc.departmentRTEÜ, Mühendislik ve Mimarlık Fakültesi, Mimarlık Bölümü
dc.description.abstractThe effort to create low-carbon societies is now more than just a need for a sustainable world. According to the sectoral energy analyses carried out to reduce world energy consumption figures and greenhouse gas emissions, buildings are one of the most striking potential measures within the net zero target of the International Energy Agency (IEA) by 2050. Low/zero carbon standards are developed in this regard, which basically propose low-emission design and operational performance for buildings. Rather than using conventional insulation materials and techniques, drastic measures like thermal superinsulation are required to meet these standards in buildings. Among thermal superinsulation materials, aerogel blankets (ABs) and vacuum insulation panels (VIPs) attract attention day after day owing to their very low thermal conductivity ranges. Despite the slim, lightweight, and highly thermally resistive features of building envelopes retrofitted with ABs and VIPs, there are still some challenges, such as thermal bridges, hot and cold spots, durability, and especially cost issues. The aforesaid challenges usually take place when a wrong decision is made to internal or external insulation. There are still numerous discrepancies in the pros and cons of internal and external thermal superinsulation retrofit. Therefore, this short communication deals with the said discussion through the in-situ performance findings of retrofitted buildings.
dc.identifier.citationMERT CÜCE, A. P., CÜCE, E., & ALVUR, E. (2024). Internal Or External Thermal Superinsulation Towards Low/Zero Carbon Buildings? A Critical Report. Gazi Journal of Engineering Sciences, 9(3), 435–442. https://doi.org/10.30855/gmbd.07050777
dc.identifier.doi10.30855/gmbd.07050777
dc.identifier.endpage442
dc.identifier.issn2149-9373
dc.identifier.issue3
dc.identifier.startpage435
dc.identifier.urihttps://doi.org/10.30855/gmbd.07050777
dc.identifier.urihttps://hdl.handle.net/11436/9404
dc.identifier.volume9
dc.indekslendigikaynakTR-Dizin
dc.institutionauthorCüce, Pınar Mert
dc.institutionauthorCüce, Erdem
dc.institutionauthorAlvur, Emre
dc.language.isoen
dc.relation.ispartofGazi Mühendislik Bilimleri Dergisi
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectInternal or external insulation
dc.subjectThermal superinsulation
dc.subjectThermal bridges
dc.subjectAerogel blanket
dc.subjectVacuum insulation panel
dc.titleInternal or external thermal superinsulation towards low/zero carbon buildings? A critical report
dc.title.alternativeDüşük/sıfır karbonlu binalara yönelik i?ç veya dış ısı yalıtımı? Kritik bir rapor
dc.typeArticle

Dosyalar

Orijinal paket

Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
cüce-2023.pdf
Boyut:
1.38 MB
Biçim:
Adobe Portable Document Format
Açıklama:
Tam Metin / Full Text

Lisans paketi

Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
license.txt
Boyut:
1.44 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: