Basit öğe kaydını göster

dc.contributor.authorKayacı, Selim
dc.contributor.authorBaş, Orhan
dc.contributor.authorBeyazal Çeliker, Fatma
dc.contributor.authorÜçüncü, Yılmaz
dc.contributor.authorArslan, Yusuf Kemal
dc.contributor.authorÖzveren, Mehmet Faik
dc.contributor.authorAykol, Şükrü
dc.date.accessioned2020-12-19T19:35:23Z
dc.date.available2020-12-19T19:35:23Z
dc.date.issued2020
dc.identifier.citationKayaci, S., Bas, O., Celiker, F. B., Ucuncu, Y., Arslan, Y. K., Ozveren, M. F., & Aykol, S. (2020). Comparison of Thalamus Volume on Magnetic Resonance and Cadaveric Section Images. Turkish neurosurgery, 30(4), 491–500. https://doi.org/10.5137/1019-5149.JTN.24530-18.2en_US
dc.identifier.issn1019-5149
dc.identifier.urihttps://doi.org/10.5137/1019-5149.JTN.24530-18.2
dc.identifier.urihttps://hdl.handle.net/11436/1280
dc.descriptionARSLAN, YUSUF KEMAL/0000-0003-1308-8569en_US
dc.descriptionWOS: 000551172600004en_US
dc.descriptionPubMed: 30649832en_US
dc.description.abstractAIM: To measure and to compare the volume of thalamus using magnetic resonance imaging (MRI) and the anatomical sections. MATERIAL and METHODS: in this study, 13 brain specimens were used. First, the images were taken in 3 mm sections on MRI, the thickness of the thalamus was measured. Subsequently, 4 mm coronal sections were prepared using amicrotome. the thalamic volumes calculated from cadaveric specimens were compared with the measurements obtained using MRI. RESULTS: on MRI, the mean thalamic volumes on the right and left hemispheres were found to be 5843.4. 361.6 mm(3) and 5377.0 +/- 666.2 mm(3) respectively. the mean volumes of the cadaveric sections were 5610.8 +/- 401.3 mm(3) on the right side and 5618.5 +/- 604.1 mm(3) on the left hemisphere. No statistically significant difference was found between the volume calculated from MRI and that obtained from the cadaveric section (p<0.05). CONCLUSION: This study shows a correlation between measurement of thalamus volume based on MRI and those calculated from anatomical sections. Our findings support the reliability of DBS procedures using MRI and stereotactic method.en_US
dc.language.isoengen_US
dc.publisherTurkish Neurosurgical Socen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectCadaveren_US
dc.subjectDeep brain stimulationen_US
dc.subjectMagnetic resonance imagingen_US
dc.subjectPlanimetry techniqueen_US
dc.subjectThalamusen_US
dc.titleComparison of thalamus volume on magnetic resonance and cadaveric section imagesen_US
dc.typearticleen_US
dc.contributor.departmentRTEÜ, Tıp Fakültesi, Dahili Tıp Bilimleri Bölümüen_US
dc.contributor.institutionauthorBeyazal Çeliker, Fatma
dc.contributor.institutionauthorÜçüncü, Yılmaz
dc.identifier.doi10.5137/1019-5149.JTN.24530-18.2
dc.identifier.volume30en_US
dc.identifier.issue4en_US
dc.identifier.startpage491en_US
dc.identifier.endpage500en_US
dc.relation.journalTurkish Neurosurgeryen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster