Basit öğe kaydını göster

dc.contributor.authorErsunan, Gökhan
dc.contributor.authorBilir, Özlem
dc.contributor.authorKalkan, Asım
dc.contributor.authorKalkan, Yıldıray
dc.contributor.authorÖzel, Deniz
dc.contributor.authorKayayurt, Kamil
dc.contributor.authorYavaşi, Özcan
dc.date.accessioned2020-12-19T19:41:30Z
dc.date.available2020-12-19T19:41:30Z
dc.date.issued2018
dc.identifier.citationErsunan, G., Bilir, Ö., Kalkan, A., Kalkan, Y., Özel, D., Kayayurt, K. & Yavaşi, Ö. (2018). Utility of near infrared spectrophotometry in mesenteric ischemia: An experimental study. Journal of Near Infrared Spectroscopy, 26(4), 235-244. https://doi.org/10.1177/0967033518791347en_US
dc.identifier.issn0967-0335
dc.identifier.issn1751-6552
dc.identifier.urihttps://doi.org/10.1177/0967033518791347
dc.identifier.urihttps://hdl.handle.net/11436/1789
dc.descriptionKalkan, Asim/0000-0002-5800-0201en_US
dc.descriptionWOS: 000444424600004en_US
dc.description.abstractThis study investigated the effectiveness of near infrared (NIR) spectrophotometry for measuring abdominal saturation in a rat model of induced mesenteric ischemia. This was a randomized, controlled, non-blinded interventional animal study. Twenty-eight male Sprague Dawley rats were randomly allocated into four groups. Following induction of anesthesia, the abdominal region was shaved and intra-abdominal access was achieved through a 4-cm midline incision and basal measurements were performed using an INVOS-5100c device. the rats were grouped on the basis of rSO2 measurement times. Mesenteric artery ligation was not performed on the control group rats. From the rest of the mesenteric artery ligated rats, measurements were taken at 30 min, at 2 h and at 6 h. Measurements were repeated using NIR spectrophotometry probes after the abdomen was surgically closed. Following the measurements, the abdomen was re-opened and small intestine tissue specimens were taken for histopathological examination. Initial and final NIR spectrophotometry measurements were compared. No statistically significant difference was found in the group 1 between basal rSO2 values and post-incision values (p = 0.748). There was a significant variation between the initial and final measurements in groups 2, 3, and 4 (p = 0.018). Although various radiological or biochemical markers are available for detecting mesenteric ischemia, the use of NIR spectrophotometry can be considered a good non-invasive alternative method for early diagnosis of acute mesenteric ischemia.en_US
dc.language.isoengen_US
dc.publisherSage Publications Ltden_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectMesenteric ischemiaen_US
dc.subjectCerebral oximetryen_US
dc.subjectAbdominal oxygenationen_US
dc.titleUtility of near infrared spectrophotometry in mesenteric ischemia: An experimental studyen_US
dc.typearticleen_US
dc.contributor.departmentRTEÜ, Tıp Fakültesi, Cerrahi Tıp Bilimleri Bölümüen_US
dc.contributor.institutionauthorErsunan, Gökhan
dc.contributor.institutionauthorBilir, Özlem
dc.contributor.institutionauthorKalkan, Yıldıray
dc.contributor.institutionauthorYavaşi, Özcan
dc.identifier.doi10.1177/0967033518791347
dc.identifier.volume26en_US
dc.identifier.issue4en_US
dc.identifier.startpage235en_US
dc.identifier.endpage244en_US
dc.relation.journalJournal of Near Infrared Spectroscopyen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster