Non-enzymatic phenol determination in river water over modified electrode with poly(3-methylthiophene)

Göster/Aç

Tam Metin / Full Text (1.194Mb)

Erişim

info:eu-repo/semantics/openAccess

Tarih

2016

Yazar

Kavanoz, Muammer
Bük, Ufuk
Ülker, Emine

Üst veri

Tüm öğe kaydını göster

Künye

Kavanoz, M., Bük, U. & Ülker, E. (2016). Non-enzymatic phenol determination in river water over modified electrode with poly(3-methylthiophene). Hittite Journal of Science and Engineering, 3(1), 35-40.

Özet

T his paper describes non-enzymatic phenol determination using poly(3methylthiophene) coated Pt electrode. Modified electrode was prepared on Pt disc surface in dichloromethane medium containing 500 mM 3-methylthiophene (3MT) and 100 mM tetrabuthylammonium perchlorate (TBAP). This electrode was used for amperometric determination of phenol in NaHSO4 / Na2SO4 (SBS) solution at pH 2.0. For this purpose, 0.70, 0.80 and 0.90 V potentials were applied and results were compared. Limit of detection and linear range were found as 4.22x10-5 and 1.41x104 - 4.00 mM (with R2=0.9932) at 0.90 V working potential, respectively. Repeatability of method was tested by using at least three modified electrode for 0.5, 1.0 and 2.0 mM phenol concentrations and relative standard deviation (RSD were found as 2.49%, 1.92% and 2.75%, respectively. To test the accuracy of method and matrix effect, phenol determination was carried out for 1.0 and 2.0 mM phenol concentrations in artificially contaminated river water samples at optimum condition and recovery values were found as 96.44% and 99.60%, respectively. Proposed method was found as simple, rapid and economic for phenol determination.

Kaynak

Hittite Journal of Science and Engineering

Cilt

3

Sayı

1

Bağlantı

https://app.trdizin.gov.tr/makale/TWpFMk5UazBOQT09
https://hdl.handle.net/11436/5929

Koleksiyonlar

  • FEF, Kimya Bölümü Koleksiyonu [474]
  • TR-Dizin İndeksli Yayınlar Koleksiyonu [2844]



DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 




| Yönerge | Rehber | İletişim |

DSpace@RTEÜ

by OpenAIRE
Gelişmiş Arama

sherpa/romeo

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına GöreBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına Göre

Hesabım

GirişKayıt

İstatistikler

Google Analitik İstatistiklerini Görüntüle

DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 


|| Rehber|| Yönerge || Kütüphane || Recep Tayyip Erdoğan Üniversitesi || OAI-PMH ||

Recep Tayyip Erdoğan Üniversitesi, Rize, Türkiye
İçerikte herhangi bir hata görürseniz, lütfen bildiriniz:

Creative Commons License
Recep Tayyip Erdoğan Üniversitesi Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@RTEÜ:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.