• Türkçe
    • English
  • Türkçe 
    • Türkçe
    • English
  • Giriş
Öğe Göster 
  •   RTEÜ
  • Araştırma Çıktıları | TR-Dizin | WoS | Scopus | PubMed
  • WoS İndeksli Yayınlar Koleksiyonu
  • Öğe Göster
  •   RTEÜ
  • Araştırma Çıktıları | TR-Dizin | WoS | Scopus | PubMed
  • WoS İndeksli Yayınlar Koleksiyonu
  • Öğe Göster
JavaScript is disabled for your browser. Some features of this site may not work without it.

Experimental investigation and force analysis of flat-plate type pulsating heat pipes having ternary mixtures

Thumbnail

Göster/Aç

Full Text / Tam Metin (12.24Mb)

Erişim

info:eu-repo/semantics/closedAccess

Tarih

2021

Yazar

Markal, Burak
Varol, Ramazan

Üst veri

Tüm öğe kaydını göster

Künye

Markal, B. & Varol, R. (2021). Experimental investigation and force analysis of flat-plate type pulsating heat pipes having ternary mixtures. International Communications in Heat and Mass Transfer, 121, 105084. https://doi.org/10.1016/j.icheatmasstransfer.2020.105084

Özet

Comprehensive experiments are conducted to analyze complex heat transfer characteristics and flow nature of a flat plate closed loop pulsating heat pipe charged with ternary mixtures. Consecutive channels of the heat pipe have different cross sections. Fluids forming the mixtures are deionized water (W), methanol (M) and pentane (P). Effects of different volume mixing ratios of these fluids (W:M:P = 1:1:1, 1:2:3 and 1:3:2) on thermal performance are evaluated comparatively with pure counterparts. Experimental range also covers other key parameters: filling ratio (30%, 50% and 70%), inclination angle (0 degrees and 901 and heat input. Flow patterns and bubble-liquid dynamics are examined. Results show that medium filling ratio of 50% presents optimum performance for all mixing ratios. At vertical orientation, ternary mixtures, especially the ones having higher content of pentane or methanol (1:2:3 and 1:3:2), show significantly better thermal characteristics compared to pure fluids. However, heat pipes charged with ternary mixtures are highly dependent on gravity; such that flat plate closed loop pulsating heat pipe having mixtures cannot operate in horizontal position. In usage of ternary mixtures, liquid droplets flowing down through channels are observed; this is called as rewetting phenomenon enhancing thermal performance. Force analysis characterizing thermo-fluid-geometric coupling is conducted

Kaynak

International Communications in Heat and Mass Transfer

Cilt

121

Bağlantı

https://doi.org/10.1016/j.icheatmasstransfer.2020.105084
https://hdl.handle.net/11436/6498

Koleksiyonlar

  • Enerji Sistemleri Mühendisliği Bölümü Koleksiyonu [117]
  • Makine Mühendisliği Bölümü Koleksiyonu [329]
  • Scopus İndeksli Yayınlar Koleksiyonu [5931]
  • WoS İndeksli Yayınlar Koleksiyonu [5260]



DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 




| Yönerge | Rehber | İletişim |

DSpace@RTEÜ

by OpenAIRE
Gelişmiş Arama

sherpa/romeo

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına GöreBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına Göre

Hesabım

GirişKayıt

İstatistikler

Google Analitik İstatistiklerini Görüntüle

DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 


|| Rehber|| Yönerge || Kütüphane || Recep Tayyip Erdoğan Üniversitesi || OAI-PMH ||

Recep Tayyip Erdoğan Üniversitesi, Rize, Türkiye
İçerikte herhangi bir hata görürseniz, lütfen bildiriniz:

Creative Commons License
Recep Tayyip Erdoğan Üniversitesi Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@RTEÜ:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.