• Türkçe
    • English
  • Türkçe 
    • Türkçe
    • English
  • Giriş
Öğe Göster 
  •   RTEÜ
  • Araştırma Çıktıları | TR-Dizin | WoS | Scopus | PubMed
  • WoS İndeksli Yayınlar Koleksiyonu
  • Öğe Göster
  •   RTEÜ
  • Araştırma Çıktıları | TR-Dizin | WoS | Scopus | PubMed
  • WoS İndeksli Yayınlar Koleksiyonu
  • Öğe Göster
JavaScript is disabled for your browser. Some features of this site may not work without it.

Development of a new and facile carrier element-free coprecipitation procedure for separation, preconcentration and sensitive determination of Cu(II) and Cd(II) Ions in water and vegetable samples

Thumbnail

Göster/Aç

Full Text / Tam Metin (1.303Mb)

Erişim

info:eu-repo/semantics/closedAccess

Tarih

2023

Yazar

Duran, Celal
Özdeş, Duygu
Menteşe, Emre
Bektaş, Hakan

Üst veri

Tüm öğe kaydını göster

Künye

Duran, C., Özdeş, D., Menteşe, E. & Bektaş, H. (2023). Development of a New and Facile Carrier Element-Free Coprecipitation Procedure for Separation, Preconcentration and Sensitive Determination of Cu(II) and Cd(II) Ions in Water and Vegetable Samples. Analytical Letters. https://doi.org/10.1080/00032719.2023.2203498

Özet

A facile and sensitive method predicated on carrier element free coprecipitation (CEFC) using 2-(2-(2-(4-bromobenzyl)-1H-benzo[d]imidazole-1-yl)acetyl)-N-ethylhydrazine-1-carbothioamide (BIMANEC) is reported for trace determination of Cu(II) and Cd(II) in vegetables and water. BIMANEC was used for the first time for the quantitative determination of these trace heavy metals. Flame atomic absorption spectrometer (FAAS) was used for quantitation. The preconcentration conditions were optimized with respect to pH (8.0), BIMANEC mass (4.0 mg), volume of sample (100 mL), standing time (5 min), and centrifugation time and rate (3 min and 2500 rpm). The influence of potentially interfering ions was scrutinized for the recovery of analyte ions. Under the optimum conditions, the limits of detection (LODs) were 0.51 and 2.28 mu g L-1 for Cu(II) and Cd(II), respectively. The relative standard deviations were < 5% for both. The recoveries from the spiked vegetable samples were from 94.9 to 102.8% and from the spiked water samples between 93.2 and 101.6%. Consequently the developed new, facile, rapid, and highly efficient CEFC process was employed for the trace determination of Cu(II) and Cd(II).

Kaynak

Analytical Letters

Bağlantı

https://doi.org/10.1080/00032719.2023.2203498
https://hdl.handle.net/11436/8199

Koleksiyonlar

  • FEF, Kimya Bölümü Koleksiyonu [474]
  • Scopus İndeksli Yayınlar Koleksiyonu [5931]
  • WoS İndeksli Yayınlar Koleksiyonu [5260]



DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 




| Yönerge | Rehber | İletişim |

DSpace@RTEÜ

by OpenAIRE
Gelişmiş Arama

sherpa/romeo

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına GöreBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına Göre

Hesabım

GirişKayıt

İstatistikler

Google Analitik İstatistiklerini Görüntüle

DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 


|| Rehber|| Yönerge || Kütüphane || Recep Tayyip Erdoğan Üniversitesi || OAI-PMH ||

Recep Tayyip Erdoğan Üniversitesi, Rize, Türkiye
İçerikte herhangi bir hata görürseniz, lütfen bildiriniz:

Creative Commons License
Recep Tayyip Erdoğan Üniversitesi Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@RTEÜ:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.