Thermal performance evaluation of a solar air heater integrated with helical tubes carrying phase change material

Thumbnail

Göster/Aç

Full Text / Tam Metin (1.784Mb)

Erişim

info:eu-repo/semantics/closedAccess

Tarih

2020

Yazar

Saxena, Abhishek
Agarwal, Nitin
Cüce, Erdem

Üst veri

Tüm öğe kaydını göster

Künye

Saxena, A., Agarwal, N. & Cüce, E. (2020). Thermal performance evaluation of a solar air heater integrated with helical tubes carrying phase change material. Journal of Energy Storage, 30, 101406. https://doi.org/10.1016/j.est.2020.101406

Özet

In this present work, the efforts have been made to improve the efficiency of solar air heater (SAH). For this, total two models have been developed. There is one reference model SAH-A and one modified model SAH-B which is integrated with paraffin wax as a low cost energy storage material. Furthermore, model SAH-B is further modified into a new model SAH-C which is integrated with a specific mixture of paraffin wax and Granular coarbon powder (GCP). For better heat storage capacity of the aforesaid energy materials, helical tube of copper made has been considered as a container. Both the models of air heater (SAH-B and SAH-C) have been experimentally tested on natural and forced convection under the climatic conditions of Moradabad city, India. Results show that SAH- C is better over SAH-A and SAH-B in performance comparison. Thermal efficiency of SAH-C is found to be 79.10%, whereas it is found around 57.41% for SAH-B and around 50% for SAH-A. the other major parameter is heat transfer coefficient and for SAH-C it is found to be 411.05 W/m(2)K, whereas it is found around 389 W/m 2 K for SAH-B and around 249.19 W/m(2)K for SAH-A. the maximum exhaust temperature of SAH-C is reported to be 52.5 degrees C, whereas it is observed around 46.9 degrees C for SAH-B and about to be 44.7 degrees C for SAH-A. the main parameters of the present work summarizes that the model SAH-C is an economic and optimum model for space heating, timber seasoning, drying operations etc. the total cost of the best configured SAH-C model is only $67.

Kaynak

Journal of Energy Storage

Cilt

30

Bağlantı

https://doi.org/10.1016/j.est.2020.101406
https://hdl.handle.net/11436/1057

Koleksiyonlar

  • Makine Mühendisliği Bölümü Koleksiyonu [329]
  • Scopus İndeksli Yayınlar Koleksiyonu [5931]
  • WoS İndeksli Yayınlar Koleksiyonu [5260]



DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 




| Yönerge | Rehber | İletişim |

DSpace@RTEÜ

by OpenAIRE
Gelişmiş Arama

sherpa/romeo

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına GöreBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına Göre

Hesabım

GirişKayıt

İstatistikler

Google Analitik İstatistiklerini Görüntüle

DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 


|| Rehber|| Yönerge || Kütüphane || Recep Tayyip Erdoğan Üniversitesi || OAI-PMH ||

Recep Tayyip Erdoğan Üniversitesi, Rize, Türkiye
İçerikte herhangi bir hata görürseniz, lütfen bildiriniz:

Creative Commons License
Recep Tayyip Erdoğan Üniversitesi Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@RTEÜ:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.