Basit öğe kaydını göster

dc.contributor.authorSaxena, Abhishek
dc.contributor.authorAgarwal, Nitin
dc.contributor.authorCüce, Erdem
dc.date.accessioned2020-12-19T19:34:21Z
dc.date.available2020-12-19T19:34:21Z
dc.date.issued2020
dc.identifier.citationSaxena, A., Agarwal, N. & Cüce, E. (2020). Thermal performance evaluation of a solar air heater integrated with helical tubes carrying phase change material. Journal of Energy Storage, 30, 101406. https://doi.org/10.1016/j.est.2020.101406en_US
dc.identifier.issn2352-152X
dc.identifier.urihttps://doi.org/10.1016/j.est.2020.101406
dc.identifier.urihttps://hdl.handle.net/11436/1057
dc.descriptionCuce, Erdem/0000-0003-0150-4705en_US
dc.descriptionWOS: 000559034800001en_US
dc.description.abstractIn this present work, the efforts have been made to improve the efficiency of solar air heater (SAH). For this, total two models have been developed. There is one reference model SAH-A and one modified model SAH-B which is integrated with paraffin wax as a low cost energy storage material. Furthermore, model SAH-B is further modified into a new model SAH-C which is integrated with a specific mixture of paraffin wax and Granular coarbon powder (GCP). For better heat storage capacity of the aforesaid energy materials, helical tube of copper made has been considered as a container. Both the models of air heater (SAH-B and SAH-C) have been experimentally tested on natural and forced convection under the climatic conditions of Moradabad city, India. Results show that SAH- C is better over SAH-A and SAH-B in performance comparison. Thermal efficiency of SAH-C is found to be 79.10%, whereas it is found around 57.41% for SAH-B and around 50% for SAH-A. the other major parameter is heat transfer coefficient and for SAH-C it is found to be 411.05 W/m(2)K, whereas it is found around 389 W/m 2 K for SAH-B and around 249.19 W/m(2)K for SAH-A. the maximum exhaust temperature of SAH-C is reported to be 52.5 degrees C, whereas it is observed around 46.9 degrees C for SAH-B and about to be 44.7 degrees C for SAH-A. the main parameters of the present work summarizes that the model SAH-C is an economic and optimum model for space heating, timber seasoning, drying operations etc. the total cost of the best configured SAH-C model is only $67.en_US
dc.language.isoengen_US
dc.publisherElsevieren_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectSolar air heateren_US
dc.subjectHeat transferen_US
dc.subjectEnergy storageen_US
dc.subjectThermal efficiencyen_US
dc.titleThermal performance evaluation of a solar air heater integrated with helical tubes carrying phase change materialen_US
dc.typearticleen_US
dc.contributor.departmentRTEÜ, Mühendislik ve Mimarlık Fakültesi, Makine Mühendisliği Bölümüen_US
dc.contributor.institutionauthorCüce, Erdem
dc.identifier.doi10.1016/j.est.2020.101406
dc.identifier.volume30en_US
dc.relation.journalJournal of Energy Storageen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster