• Türkçe
    • English
  • Türkçe 
    • Türkçe
    • English
  • Giriş
Öğe Göster 
  •   RTEÜ
  • Araştırma Çıktıları | TR-Dizin | WoS | Scopus | PubMed
  • WoS İndeksli Yayınlar Koleksiyonu
  • Öğe Göster
  •   RTEÜ
  • Araştırma Çıktıları | TR-Dizin | WoS | Scopus | PubMed
  • WoS İndeksli Yayınlar Koleksiyonu
  • Öğe Göster
JavaScript is disabled for your browser. Some features of this site may not work without it.

Electrode prepared with combination of different conductive polymers for hydroquinone determination in river water

Thumbnail

Göster/Aç

Full Text / Tam Metin (381.2Kb)

Erişim

info:eu-repo/semantics/openAccess

Tarih

2016

Yazar

Ülker, Emine
Kavanoz, Muammer

Üst veri

Tüm öğe kaydını göster

Künye

Ülker, E., & Kavanoz, M. (2016). Electrode Prepared with Combination of Different Conductive Polymers for Hydroquinone Determination in River Water. Acta chimica Slovenica, 63(1), 47–54. https://doi.org/10.17344/acsi.2015.1897

Özet

Modified electrode based on combination of different conductive polymers (polyaniline -poly(3-methylthiophene) poly( 3,3'-diaminobenzidine) (PANI - P3MT - PDAB)) was previously synthesized in dichloromethane containing HClO4 and tetrabutylammoniumperchlorate (TBAP) as supporting electrolyte. Herein, the determination of hydroquinone (HQ) with amperometric I-t method over this modified and its homopolymers coated electrode was successfully carried out in river water as a real sample and in solution consisting of NaHSO4/Na2SO4 (pH 2.0). For this method, potentials between 0.45 V and 0.65 V were applied and the best analytical response was obtained at 0.55 V using this modified electrode when compared to its homopolymers. the limit of detection (LOD), limit of quantification (LOQ), the linear dynamic range and regression coefficient (R-2) were found as 1.31 x 10(-4) mM, 4.37 x 10(-4) mM, 4.37 x 10(-4)-95.0 mM and 0.998, respectively. These results were compared to homopolymers coated and uncoated Pt electrodes. For checking on the accuracy of the developed method and the matrices interference, determination of HQ was performed in artificially contaminated river water samples with HQ concentration of 5.0 mM and 10.0 mM using this modified electrode and recovery values were calculated as 100.6% and 100.1%, respectively.

Kaynak

Acta Chimica Slovenica

Cilt

63

Sayı

1

Bağlantı

https://hdl.handle.net/11436/2682

Koleksiyonlar

  • FEF, Kimya Bölümü Koleksiyonu [476]
  • PubMed İndeksli Yayınlar Koleksiyonu [2443]
  • Scopus İndeksli Yayınlar Koleksiyonu [5990]
  • WoS İndeksli Yayınlar Koleksiyonu [5260]



DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 




| Yönerge | Rehber | İletişim |

DSpace@RTEÜ

by OpenAIRE
Gelişmiş Arama

sherpa/romeo

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına GöreBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına Göre

Hesabım

GirişKayıt

İstatistikler

Google Analitik İstatistiklerini Görüntüle

DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 


|| Rehber|| Yönerge || Kütüphane || Recep Tayyip Erdoğan Üniversitesi || OAI-PMH ||

Recep Tayyip Erdoğan Üniversitesi, Rize, Türkiye
İçerikte herhangi bir hata görürseniz, lütfen bildiriniz:

Creative Commons License
Recep Tayyip Erdoğan Üniversitesi Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@RTEÜ:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.