• Türkçe
    • English
  • Türkçe 
    • Türkçe
    • English
  • Giriş
Öğe Göster 
  •   RTEÜ
  • Araştırma Çıktıları | TR-Dizin | WoS | Scopus | PubMed
  • WoS İndeksli Yayınlar Koleksiyonu
  • Öğe Göster
  •   RTEÜ
  • Araştırma Çıktıları | TR-Dizin | WoS | Scopus | PubMed
  • WoS İndeksli Yayınlar Koleksiyonu
  • Öğe Göster
JavaScript is disabled for your browser. Some features of this site may not work without it.

Evaluation of monomer elution, microhardness, and roughness of experimental dental composite resins prepared from Bis-EFMA, a novel monomer system

Thumbnail

Göster/Aç

Full Text / Tam Metin (2.117Mb)

Erişim

info:eu-repo/semantics/closedAccess

Tarih

2021

Yazar

Hatipoğlu, Ömer
Turumtay, Emine Akyüz
Saygın, Ayşegül Göze

Üst veri

Tüm öğe kaydını göster

Künye

Hatipoglu, O., Turumtay, E.A. & Saygin, A.G. (2021). Evaluation of monomer elution, microhardness, and roughness of experimental dental composite resins prepared from Bis-EFMA, a novel monomer system. Polymer Composites, 43(1), 584-592. https://doi.org/10.1002/pc.26401

Özet

This study aimed to compare the monomer elution, microhardness, and roughness of experimental resin-based composites (RBCs) prepared from a novel monomer system derived from 9,9-Bis[4-(2-hydroxyethoxy)phenyl]fluorene) (Bis-EFMA), bisphenol A-glycidyl methacrylate (Bis-GMA), and urethane dimethacrylate (UDMA) with each other, also with a commercial RBC, 3 M ESPE FiltekTM Z250 (FZ). Experimental Bis-EFMA (ET), Bis-GMA (BT), and UDMA (UT) based composites were prepared (20% Bis-EFMA or 20% Bis-GMA or 20% UDMA, and 20% triethylene glycol dimethacrylate [TEGDMA], and 60% glass filler). 60 specimens were produced (n = 5) and exposed to ethanol solution for 7 days. Then specimens were tested at baseline (T0), first (T1), third (T2), and seventh (T3) days. ET and FZ released significantly lower TEGDMA than other RBCs did (p < 0.05). BT released significantly higher TEGDMA than other RBCs did at T1 (p < 0.05). However, no significant difference was found between FZ and ET at T1 (p > 0.05). FZ exhibited the highest microhardness at all-time points; besides, the microhardness of BT was lowest at T0, while the microhardness of BT and UT was lower than that of FZ and ET at T1, T2, and T3 (p < 0.05). BT exhibited higher roughness at T2 than the UT did at T0 and T1, significantly (p < 0.05). However, no significant difference was found between the other RBCs (p > 0.05). Bis-EFMA, a novel bisphenol A-free monomer system, has the potential to be used in commercial RBCs as a substitute for Bis-GMA in terms of lower monomer elution and higher microhardness.

Kaynak

Polymer Composites

Cilt

43

Sayı

1

Bağlantı

https://doi.org/10.1002/pc.26401
https://hdl.handle.net/11436/6681

Koleksiyonlar

  • FEF, Kimya Bölümü Koleksiyonu [476]
  • Scopus İndeksli Yayınlar Koleksiyonu [5990]
  • WoS İndeksli Yayınlar Koleksiyonu [5260]



DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 




| Yönerge | Rehber | İletişim |

DSpace@RTEÜ

by OpenAIRE
Gelişmiş Arama

sherpa/romeo

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına GöreBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına Göre

Hesabım

GirişKayıt

İstatistikler

Google Analitik İstatistiklerini Görüntüle

DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 


|| Rehber|| Yönerge || Kütüphane || Recep Tayyip Erdoğan Üniversitesi || OAI-PMH ||

Recep Tayyip Erdoğan Üniversitesi, Rize, Türkiye
İçerikte herhangi bir hata görürseniz, lütfen bildiriniz:

Creative Commons License
Recep Tayyip Erdoğan Üniversitesi Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@RTEÜ:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.